Over 1000 psi – entire system must be 316 stainless steel.
Applicable only to hydrogen.
Monel and 316 stainless steel are acceptable for oxygen service, provided the
instrument has been cleaned for oxygen service and is free from oil.
Oxalic Acid
Oxygen (Gas)
Palmitic Acid >99%
Phosphoric Acid <80%
Picric Acid <10%
Propane (Dry)
Sea Water (Flowing)
Silver Nitrate <70%
Sodium Bicarbonate <20%
Sodium Bisulfate <30%
Sodium Carbonate <40%
Sodium Chromate <60%
Sodium Cyanide
Sodium Hydroxide < 40%
Sodium Hypochlorite <25%
Sodium Phosphate, Tri <60%
Sodium Silicate <50%
Sodium Sulfide <50%
Stannous Chloride <10%
Steam (Use siphon)
Stearic Acid
Sulfur Dioxide (Dry) >99%
Sulfur Trioxide (Dry) >99%
Sulfuric Acid
Tannic Acid <80%
Tartaric Acid <50%
Tin Chloride (ous) <10%
Toluene >99%
Turpentine >98%
Water (Tap)
Whiskey
Zinc Chloride <25%
Zinc Sulphate <40%
Crude Oil (Sour)
Crude Oil (Sweet)
Ethyl Acetate
Ethylene Oxide >99%
Ferric Chloride <40%
Ferric Sulfate <10%
Ferrous Chloride <30%
Ferrous Sulfate <50%
Fluorine Gas (Dry)
Formaldehyde <95%
Formic Acid
Freons
Furfural <10%
Gasoline
Glycerin >99%
Hydrobromic Acid
Hydrochloric Acid
Hydrofluoric Acid
Hydrofluosilic Acid
Hydrogen
Hydrogen Peroxide <50%
Kerosene
Lactic Acid <70%
Magnesium Chloride <40%
Mercuric Chloride <60%
Mercury >99%
Milk
Naphtha >99%
Naphthalene >99%
Nickel Chloride >99%
Nitric Acid <95%
Nitrogen
Oleic Acid
Acetone
Acetic Acid <40%
Acetic Anhydride
Acetylene (Dry)
Acrolein 100%
Air
Alcohol, Ethyl
Alum. Chloride >10%
Alum. Sulfate 10-50%
Ammonia Gas (Dry)
Ammonium Chloride <40%
Ammonium Nitrate <50%
Ammonium Sulfate <60%
Aniline>99%
Argon
Beer
Benzidine >99%
Benzene <50%
Benzoic Acid <70%
Boric Acid <25%
Bromine (Dry)
Butane
Butyric Acid <10%
Calcium Chloride <80%
Calcium Hydroxide <50%
Carbon Dioxide
Carbon Monoxide >99%
Chlorine (Dry)
Chlorine (Moist)
Chloroform (Dry)
Chromic Acid
Citric Acid 10-50%
Corn Oil
Media Application Table
Ashcroft
®
Duragauge
®
Pressure Gauge
The media being measured must be
compatible with the wetted parts of the
pressure instrument. To use the chart
below, locate the media whose pressure
is to be measured and select a suitable
material from those available. Diaphragm
seal information is contained in Bulletin
DS-1. This is a simplified chart and
assumes the media temperature is
below 200°F.
PLUS!
option, throttling
devices and/or a liquid-filled instrument
are recommended in applications with
pulsation or vibration. These recommen-
dations are only a guide, as service life is
dependent on temperature, concentra-
tions, catalysts that may be added, or
other conditions beyond our control.
Consult Stratford, CT customer service
for specific applications and for any
media not listed. More complete corro-
sion guide available on our website at
www.dresserinstrument.com
in the
Application Data Section.
Media
Application
Media
Application
Media
Application
*
Any standard Bourdon tube material may be used in conjunction with a diaphragm
seal, but the gauge selection should take into consideration the corrosive environment
in which it is to operate. For diaphragm seals see Bulletin DS-1.
Brass or bronze
Steel
Stainless steel
Monel
Diaphragm seals*
Brass or bronze
Steel
Stainless steel
Monel
Diaphragm seals*
Brass or bronze
Steel
Stainless steel
Monel
Diaphragm seals*
Pressure Instrument
Material
Pressure Instrument
Material
Pressure Instrument
Material
9