Pilgrim Pressure Switches B-SERIES Uživatelský manuál Strana 5

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 4
5
ORDER INFORMATION
B-SERIES PRESSURE AND DIFFERENTIAL PRESSURE
SWITCH MODEL NUMBER:
To specify the exact switch desired, select entries from appropriate tables
as shown in example below.
B 4 2 0 B X P K
600 PSI
1234
5
1 – ENCLOSURE
Pressure switch, Type 400, watertight enclosure
B4
meets NEMA 3, 4, 4X, 13 and IP66 requirements.
Pressure switch, Type 700, explosion-proof
B7 enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66
requirements.
Differential pressure switch, Type 400, water-
D4 tight enclosure meets NEMA 3, 4, 4X, 13 and
IP66 requirements.
Differential pressure switch, Type 700, explosion-
D7 proof enclosure meets Div. 1 & 2, NEMA 7, 9 and
IP66 requirements.
2 – SWITCH ELEMENT SELECTION
Order Switch Elements
Code UL/CSA Listed SPDT
20
(7)
Narrow deadband ac 15A, 125/250 Vac
21 Ammonia service 5A, 125/250 Vac
22
(6)
Hermetically sealed switch, 5A, 125/250 Vac
narrow deadband
23 Heavy duty ac 22A, 125/250 Vac
24
(1)
General purpose 15A, 125/250/480 Vac
1
2
A, 125 Vdc
1
4
A, 250 Vdc; 6A, 30 Vdc
25
(2)
Heavy duty dc 10A, 125 Vac or dc,
1
8 HP, 125 Vac or dc
26
(7)
Sealed environment proof 15A, 125/250 Vac
27 High temperature 300°F 15A, 125/250 Vac
28
(5)
Manual reset trip on 15A, 125/250 Vac
increasing
29
(5)
Manual reset trip on 15A, 125/250 Vac
decreasing
31 Low level (gold) contacts 1A, 125 Vac
32 Hermetically sealed switch, 11A, 125/250 Vac
general purpose 5A, 30 Vdc
42 Hermetically sealed switch, 1A, 125 Vac
gold contacts
50 Variable deadband 15A, 125/250 Vac
UL/CSA Listed Dual (2 SPDT)
61
(7)
Dual narrow deadband 15A, 125/250 Vac
62
(7)
Dual sealed environment 15A, 125/250 Vac
proof
63 Dual high temp. 300°F 15A, 125/250 Vac
64 Dual general purpose 15A, 125/250/480 Vac
1
2A, 125 Vdc
1
4A, 250 Vdc
65 Dual ammonia service 5A, 125/250 Vac
67
(4,6)
Dual hermetically sealed 5A, 125/250 Vac
switch, narrow deadband
68
(4)
Dual hermetically sealed 11A, 125/250 Vac
switch, general purpose 5A, 30 Vdc
71
(4)
Dual hermetically sealed 1A, 125 Vac
switch, gold contacts
3 – ACTUATOR SEAL
Range
Code Process
and Temperature Vac. 0-600 1000 3000
Material Limits °F
(9)
˝ H
2
O psi psi psi
B – Buna-N 0 to 150 ••••
V – Viton 20 to 300
T – Teflon 0 to 150 ••••
S – 316L
(8)
0 to 300
P – Monel
(8)
0 to 300
4 – OPTIONS
Use table from page 10
5 – RANGE
Select from table on page 4
NOTES:
1 Standard switch.
2Not available with psid ranges.
3 Dual switches are 2 SPDT snap-action switches, not
independently adjustable.
4 Wires cannot be terminated inside B400 switch
enclosure.
5Not available with type 700 enclosure.
6 Estimated dc. rating, 2.5A, 28 Vdc (not
UL listed).
7 Estimated dc rating, 0.4A, 120 Vdc (not UL listed).
8Available on pressure only.
9 Ambient operating temperature limits –20 to 150°F,
all styles, setpoint shift of ±1% of range per 50°F
temperature change is normal.
Switches are calibrated at 70°F reference.
D4 psid model shown
Zobrazit stránku 4
1 2 3 4 5 6 7 8 9 10 ... 15 16

Komentáře k této Příručce

Žádné komentáře